Jinchang Outdoor Mobile Toilet Installation
The installation of outdoor mobile toilets in Jinchang requires a comprehensive approach covering transportation deployment, on-site installation, foundation treatment, terrain adaptation, earthquake resistance design, spatial layout, and aesthetic coordination. The specific installation points are as follows:

1. Transportation and Foundation Deployment Adopt a multi-point lifting plan, with four standardized lifting points set for each module, allowing for transportation using ordinary cranes and reducing equipment requirements. Foundation treatment only requires a concrete platform or steel frame base, with a floor area controlled between 6-12 square meters, suitable for scenarios with limited space. During transportation, ensure uniform force distribution at the lifting points to prevent module deformation.
2. On-site Installation and Efficiency Modules are connected using dedicated connectors, and the installation process does not require complex tools, allowing for assembly and commissioning within 8 hours. After disassembly, the site can be restored to its original state, minimizing long-term environmental impact. Before installation, check the integrity of the connectors to ensure tightness and prevent sewage leakage.
3. Wind and Earthquake Resistance Design The foundation combines prefabricated concrete blocks with ground expansion bolts, capable of withstanding wind forces up to magnitude 8 and preventing structural displacement. A 5-centimeter buffer gap is reserved at structural connections to absorb minor ground deformation stresses, meeting earthquake resistance requirements for magnitude 8 intensity. During installation, calibrate the depth of the expansion bolts to ensure foundation stability.
4. Terrain Compatibility Adjustment By adjusting the height of the supports, stable installation can be achieved on irregular ground with slopes up to 15 degrees. Before installation, measure the ground slope and adjust the supports to a horizontal state to prevent module tilting, which could cause inconvenience in use or structural damage.
5. Spatial Layout and Barrier-Free Design The entrance passage width is maintained at over 90 centimeters, with foldable handrails and emergency call buttons installed inside for the convenience of individuals with mobility impairments. Child-specific facilities adopt independent units with reduced height, equipped with ergonomic auxiliary cushions. All sharp edges and corners are rounded, and the floor is covered with anti-slip materials to reduce safety hazards.
6. Aesthetic and Landscape Adaptation Low-saturation color schemes are selected for the exterior to harmonize with the surrounding environment and reduce visual intrusion. Vertical greening modules can be added to the facade to enhance ecological aesthetics. Before installation, confirm the color scheme and greening module specifications to ensure consistency with the overall landscape design.
During the installation process, strictly follow operational specifications, regularly inspect module connections, foundation stability, and equipment operation status to ensure long-term stable use of the mobile toilets.