Images of Keyways in Prefabricated Beams of Houses
Currently, it is not possible to directly provide images of keyways in prefabricated beams of houses, but detailed information about their relevant characteristics and specification requirements can be given.

Keyway Dimension Specifications
- Depth: The depth t of the keyway should not be less than 30mm. This is the fundamental dimension to ensure that the keyway can function effectively. If the depth is too small, it may not be able to provide sufficient shear-bearing capacity, affecting the connection performance between the prefabricated beam and the cast-in-place concrete.
- Width: The width w should not be less than three times the depth and not more than ten times the depth. For example, when the keyway depth is 30mm, its width should be in the range of 90mm - 300mm. An appropriate width range can ensure that the keyway can evenly transfer stress under load, avoiding local stress concentration and subsequent damage.
Keyway Arrangement Requirements
- Through and Non-through: Keyways can pass through the cross-section. When they do not pass through, the distance from the slot opening to the edge of the cross-section should not be less than 50mm. Through keyways can provide a more continuous connection, enhancing the overall integrity. Non-through keyways, when meeting certain distance requirements, can also ensure the load-bearing performance of the structure and may simplify the construction process to some extent.
- Spacing: The spacing between keyways should preferably be equal to the width of the keyway. Such an arrangement can ensure that the keyways are evenly distributed on the prefabricated beam, enabling more uniform stress transfer and improving the reliability and durability of the structure.
Keyway End Characteristics
The inclination angle at the end of the keyway should not be greater than 30°. A smaller end inclination angle can reduce stress concentration, avoiding premature damage at the end of the keyway under load and ensuring that the keyway can fully play its connecting role.
Special Part Setting Requirements
When setting keyways at the end of composite beams and the contact surface with cast-in-place concrete, the setting requirements for rough surfaces and keyways are detailed in Article 6.5.5 of JGJ1 - 2014. These special part setting requirements are aimed at better ensuring the bonding performance between the composite beam and the cast-in-place concrete, improving the overall load-bearing capacity and seismic performance of the structure.