Back to blog
Article

Portable Toilets for Construction Sites in Huaian County

Admin October 16, 2026

The suppliers, product features, and usage points of portable toilets for construction sites in Huaian County are as follows:

Suppliers and Contact Information
Haoshitong Pipeline Engineering (Beijing) Co., Ltd. provides rental services, with contact numbers 13611098718, 13521625753, and 010-83406278; Henan Guting Metal Products Co., Ltd. supplies the products, with the contact number 18538158718.

Core Product Features

  1. Cost-Effectiveness: Portable toilets do not require large-scale land planning and infrastructure construction. They are mainly assembled, significantly reducing labor and material inputs. They have a high return on investment and can quickly recover costs through rental or placement in high-traffic scenarios (such as scenic spots and event venues).
  2. Technical Construction:
    • Water Storage System: It adopts a hierarchical design, with independent supply of flushing water and handwashing water. The water consumption is precisely calculated to adapt to different usage frequencies.
    • Waste Treatment: Solid-liquid separation is achieved through sealed containers and biodegradable materials. Some models are equipped with activated carbon filters to control odor diffusion.
    • Spatial Isolation: Lightweight composite materials are used, balancing structural stability with the need for rapid assembly and disassembly.
  3. Material Adaptability:
    • The exterior walls are made of fiberglass (corrosion-resistant) or galvanized steel plates (impact-resistant). The internal pipes are made of polyethylene material (resistant to temperatures as low as -20°C), suitable for the winter climate in Zhangjiakou.
    • The anti-slip floor is made of embossed aluminum plates, with a friction coefficient of ≥0.6 in wet conditions; the joints are treated with silicone sealant to prevent cracking due to temperature changes.

Operating Parameters in Zhangjiakou's Climate

  1. Anti-Freezing Design: The water supply pipes are wrapped with ≥30 mm polyurethane insulation material, and the ventilation system activates a low-power warm air circulation device in winter.
  2. Anti-Sandstorm Measures: The air inlets and outlets are equipped with washable filters with a pore size of ≤0.5 mm.
  3. Power Supply Guarantee: Standard configurations include solar panels and battery packs, which can maintain basic lighting for more than 72 hours on consecutive cloudy days.

Installation and Maintenance Requirements

  1. Layout Specifications: Each unit occupies an area of 1.2m×1.2m to 1.5m×1.8m, with a device spacing of 0.8-1.2 meters. The ground flatness error should be ≤5 mm, and the inclination should be ≤1%.
  2. Cleaning System:
    • Basic cleaning involves surface disinfection every 4 hours, deep cleaning involves daily waste disposal, and excellent cleaning involves weekly pipe flushing and filter replacement.
    • Disinfectants are selected from quaternary ammonium compounds, which are stable at low temperatures and have low corrosiveness.
    • Solid waste is classified for disposal, and liquid waste must be treated in a three-stage sedimentation tank before discharge, with a suspended solids concentration of ≤50 mg/L.

Environmental Adaptability Improvements
The temperature sensor automatically enhances insulation when the average temperature over three consecutive days is < -15°C; when the usage frequency counter shows an average daily usage of > 80 times, additional backup units are required; the air quality monitor operates continuously.