The method of building the base of a mobile toilet varies depending on its type. Here are the common steps for building the base of a municipal mobile toilet:

Thorough Preparation Work
Before installing the base of a municipal mobile toilet, conduct a comprehensive inspection of the equipment and accessories. Check if the base support has any deformation. If it is deformed, it may lead to instability of the equipment during subsequent installation and use. Verify that all anchor bolts are present, as they are crucial components for securing the base, and their absence will affect the firmness of the installation. Also, inspect whether the rubber gaskets are aged, as aged gaskets will impact the shock-absorbing effect. Additionally, level the ground according to the actual site conditions and use a spirit level to confirm that the installation area is level. Uneven ground will affect the installation accuracy of the base and the stability of the equipment.
Fixing the Support to the Ground
Place the shock-absorbing base support of the mobile toilet steadily on the prepared ground and adjust the height of the four corners to ensure that the entire equipment is in a level state. When using expansion bolts to fix the base support, select bolts of appropriate lengths according to the ground material. For example, on a concrete ground, longer expansion bolts are required to ensure firm fixation; on softer ground materials, relatively shorter bolts can be chosen. When tightening each bolt, ensure that the tightening degree is uniform to avoid deformation of the base support due to uneven local stress.
Installation Specifications for Shock-Absorbing Devices
When installing shock-absorbing rubber pads or spring shock absorbers, ensure that they are fully in contact with the support and the ground without any misalignment or suspension. Improper installation of shock-absorbing devices will reduce the shock-absorbing effect and affect the comfort of using the mobile toilet. For bases with buffering functions, after installation, gently push the equipment to test the shock-absorbing effect. If the shock-absorbing effect is not satisfactory, check the installation of the shock-absorbing devices and make adjustments.
Post-Installation Inspection and Debugging
After installation, use a spirit level again to check the overall levelness to ensure the accuracy of the equipment installation. Check whether all connections are firm and whether the anchor bolts are tightened properly to avoid loosening during use. A simple shaking test can be conducted to confirm whether the shock-absorbing effect meets the requirements. If possible, observe the stability of the equipment within 24 hours after installation to promptly detect and resolve any potential problems.