The standards for housing prefabricated slabs mainly include aspects such as design service life, dimensions, and load-bearing grades, as detailed below:

Design Service Life: According to the current national standard 'Unified Standard for Reliability Design of Building Structures' (GB50068 - 2018), the design service life for ordinary buildings and structures, including prefabricated slab buildings, is 50 years. It should be clarified that the design service life is not a mandatory retirement age; rather, it refers to the expected safe service life of the building under normal construction, compliant materials, and timely maintenance. This means that if strict quality control is exercised during construction, compliant building materials are selected, and regular maintenance is carried out during subsequent use, the prefabricated slab structure of the building can be guaranteed to be safe for use within 50 years; with proper maintenance, its actual service life may even be longer.

Dimensions:

  • Length: The standard size range is from 3 meters to 4.2 meters, with increments of 30 centimeters. In residential buildings, 4.2-meter slabs are the most commonly used. If the length requirement exceeds this standard, customization is required.
  • Width: There are mainly two specifications: 50 centimeters and 60 centimeters. The splicing error should be controlled within 5 millimeters. Sometimes, narrow slabs of 40 centimeters are used for secondary structures to meet specific architectural layout requirements.
  • Thickness: A thickness of 12 centimeters for ordinary floor slabs meets basic usage requirements. If facilities such as water pipes and electrical wires need to be embedded in the floor slab, to ensure the structural strength and safety of the slab, its thickness should be at least 150mm.
  • Maximum Span: The maximum span of prefabricated floor slabs is 4200mm. In the southwest region, due to special geological and climatic conditions, special load-bearing slabs must be used to ensure the stability of the building structure.

Load-Bearing Grade: Ordinary residences typically use Grade 1 slabs, which have a load-bearing capacity of 1 kilonewton per square meter. In the southwest region, due to the特殊性 (special nature) of the geographical environment, when selecting prefabricated slab sizes, standard models should be chosen as much as possible to better adapt to local building requirements and usage environments, ensuring the safety and durability of the building.