Back to blog
Article

Custom Prefabricated Panels for Houses

Admin September 18, 2026

When customizing prefabricated panels for houses, it is essential to focus on the customization requirements for dimensions, load-bearing capacity, and other special considerations to ensure compliance with building codes and practical needs.

In terms of dimension customization, strict adherence to modular dimensions and limits is required. For ordinary residential prefabricated panels, the maximum length is typically 4.2 meters; lengths exceeding this require additional costs for customization. Lengths generally increase in increments of 300mm, with common specifications being 3000mm, 3300mm, 3600mm, 3900mm, and 4200mm. For special requirements, non-standard sizes such as 3800mm or 4000mm can be customized. Widths are primarily 500mm and 600mm, as these sizes facilitate seamless joining and reduce the cost of gap treatment. Thickness should be selected based on function: a standard thickness of 120mm is suitable for ordinary floors; if water pipes or electrical wires need to be embedded within the prefabricated panels, the thickness should be increased to at least 150mm to ensure space for pipeline installation and structural safety.

Load-bearing customization must match the intended usage scenario. Prefabricated panels are classified into multiple load-bearing grades. Grade 1 panels have a live load capacity of 1kN/m² and are suitable for light-load areas such as bedrooms. Grade 2 panels have a live load capacity of 2kN/m² and can meet the load-bearing requirements of frequently occupied areas like living rooms. In the southwest region, due to special geological conditions, the minimum load-bearing grade specified is Grade 4, with a live load capacity of 4kN/m² to accommodate higher load requirements. During customization, it is crucial to clarify the usage scenario to avoid structural safety hazards caused by insufficient load-bearing capacity.

Other customization considerations must adhere to professional standards. Thickness adjustments should not be made arbitrarily and must be determined by a structural engineer based on a comprehensive assessment of the overall building design, load distribution, and material properties. Unauthorized modifications may affect structural stability. Joint treatment should use professional adhesives to ensure the sealing of the joints and prevent leakage or crack propagation. Additionally, some merchants offer personalized customization services, such as special shapes or pre-drilled holes, but these are subject to the merchant's actual capabilities. Before customization, it is necessary to confirm technical feasibility and cost.

During the customization process, it is recommended to communicate thoroughly with suppliers, designers, and structural engineers to clarify requirements and verify parameters, ensuring that the prefabricated panels meet building safety standards and functional requirements.