Back to blog
Article

Container House Liuhe

Admin September 16, 2026

There are professional container house manufacturers in Liuhe District, Nanjing, such as Nanjing Zhongkai Container Technology Co., Ltd.. Here is a detailed introduction to container houses:

I. Classification and Uses of Container Houses Container houses can be classified by function into accommodation, office, commercial service, sanitary, and special-purpose types (such as medical and explosion-proof containers). By structural origin, they are divided into custom fixed-box modules (with a high degree of factory production) and variable-box modules (such as display boxes with flippable wall panels). By spatial combination, they can be single-box landings (temporary dormitories), horizontal container combinations (conference rooms), vertical stacking (multi-story dormitories), and staggered/cantilevered structures (popular guesthouses).

II. Technical Standards for Container Houses

  1. Structural Safety: They must comply with the Technical Regulations for Modular Combined Houses, with a maximum of 6 floors, a height of ≤24 meters, and an earthquake resistance of ≤8 degrees. Corner fittings are the only stacking load-bearing points. Steel must be welded weather-resistant steel (GB/T 4171), and non-box components should use Q235B/Q345B.
  2. Fire Prevention and Corrosion Resistance: Enclosure fillings must not use flammable materials like EPS. Crowded places require A-grade rock wool/glass wool with a fire resistance limit of ≥0.5 hours.
  3. Environmental Requirements: Sandwich panel cores must be A-grade non-combustible materials (rock wool or glass wool). The use of EPS polystyrene foam is prohibited, and material environmental certificates must be provided.

III. Customization and Purchase Considerations

  1. Size Specifications: The mainstream options are 20-foot (6058×2438×2591mm) or 40-foot (12192×2438×2591mm) standard containers, with non-standard customization also available (e.g., 3m×6m).
  2. Structural Safety: Choose containers with fixed devices at the bottom, column wall thickness ≥2.3mm, and fully welded frames that meet the JGJ/T 435-2018 load standard.
  3. Material Verification: Prioritize manufacturers with fire safety test reports and after-sales support, avoiding low-cost options with reduced configurations (such as thin-walled steel or non-fireproof cores).
  4. Contract Details: Clearly specify dimensions (length, width, height), steel/wall material thickness, door and window opening directions, electrical configurations, and interior decoration requirements.