Key considerations for container house foundation installation include ground treatment, hoisting and positioning, structural connections, and installation points for special types, as detailed below:

Ground treatment is the core aspect of foundation installation, and the method should be determined based on the type of container house and its intended usage period. For long-term fixed installations, a concrete strip foundation is recommended, with a width of 30-50 centimeters and a depth determined by the thickness of the frost layer. The horizontal error of the foundation top surface should be controlled within 2 millimeters per meter. For short-term use, prefabricated concrete pads or steel plates can be used, with a spacing of no more than 2 meters between pads, and a crushed stone leveling layer should be laid underneath. Direct placement on soft soil can lead to uneven settlement of the container, causing issues such as window and door deformation and wall cracks.

Hoisting and positioning require precise control of contact conditions. Container houses typically have 4-6 hoisting points at the bottom, and steel wires with matching load-bearing capacity should be used to ensure synchronous force application at all hoisting points, preventing container distortion due to unilateral force. After the container is positioned, the fit between the bottom beam and the foundation pads should be checked immediately, and thin steel plates should be used to fill any local gaps to prevent floor vibration or noise during subsequent use. Horizontal measurements should be taken along the longitudinal and transverse directions of the bottom beam, with an error tolerance of no more than 2 millimeters per meter.

Structural connections require enhanced earthquake-resistant and anti-loosening measures. When stacking multiple containers, verticality should be carefully controlled, and high-strength bolts should be used for node connections, with earthquake-resistant and anti-loosening treatments applied. For example, modular buildings should be connected to the foundation using high-strength bolts to ensure the overall structure can withstand strong typhoons and high-intensity earthquakes. Plumbing installations should comply with the 'Code for Acceptance of Construction Quality of Building Electrical Engineering' and the 'Code for Acceptance of Construction Quality of Building Water Supply and Drainage and Heating Engineering' to ensure the tightness of pipeline connections.

Installation of special types of container houses requires differentiated approaches. For foldable container houses, the stability of the steel wire ropes should be checked first, the main frame should be hoisted and unfolded, a support rod should be placed in the middle of the container to maintain stability, and then the walls should be pushed open sequentially and fixed with tightening screws. The entire process takes only 3 minutes and requires only two operators. Packing-box container houses have simple foundation requirements and can be installed on strip or mound foundations or even directly on the ground. Residential prefabricated temporary buildings require a concrete foundation and should be secured to the building with expansion bolts, but the foundation cannot be reused after demolition.