Back to blog
Article

Fire Rating of Container Houses

Admin September 15, 2026

The fire rating of container houses typically needs to reach Class A to meet fire safety requirements for residential and office scenarios.

  1. Core Requirements for Fire Rating
    According to fire safety acceptance standards, container houses used for residential and office purposes must use Class A rock wool fireproof panels. For example, the fireproof containers produced by Wuhan Delaosi Innovation Container Co., Ltd. are clearly labeled as Class A fireproof. Their wall materials achieve efficient fire resistance through rock wool sandwich panels, withstanding temperatures up to 1000-2000℃, not burning at 800℃, and having no flames at 1200℃, meeting the mandatory requirements for Class A non-combustible materials in the national standard GB/T 8624-2012.

  2. Key Measures for Fire Protection Design
    In addition to material selection, the fire protection design of container houses must be considered throughout their entire lifecycle:

  • Construction Phase: Core materials should be kept away from open flame operations such as electric welding and gas welding. Electrical wires and cables should be equipped with protective sleeves. Socket and switch boxes should be made of metal galvanized boxes and installed openly to avoid sparks igniting the sandwich materials.
  • Usage Phase: Heat sources and open flames should be kept at a safe distance from the steel plates. The kitchen area should be equipped with thermal insulation layers and additional fireproof rock wool insulation. Simple fire extinguishing equipment should be provided indoors and outdoors, and fire alarms should be installed where possible.
  • Layout Standards: A minimum safety distance of 6 meters should be maintained between color steel plate houses to prevent the spread of fire.
  1. Synergy Between Structural Safety and Fire Protection
    Fire protection performance must be designed in conjunction with structural safety, durability, and other indicators. For example, the container products of Wuhan Jinxiang Light Steel Housing Co., Ltd. use Q235B/Q345B hot-dip galvanized square steel frames, combined with Class A/B1 fireproof rock wool sandwich panels. They not only meet the requirements for withstanding winds of 10-12 levels and earthquakes of magnitude 7 and above but also extend their service life to 15-20 years through overall galvanizing or anti-corrosion coating, forming a composite safety system of "fire protection-structure-durability."

  2. Fire Protection Enhancement in Special Scenarios
    In scenarios such as emergency shelter and epidemic isolation, container houses must comply with standards such as the "Facilities and Equipment Configuration for Emergency Shelters," which mandate Class A fire protection, thermal insulation, sound insulation, and waterproofing performance, and support rapid assembly within 48 hours to ensure the integrity of the fire protection barrier under extreme conditions.