Can the Walls of Prefabricated Panel Houses Be Knocked Down?
Whether the walls of prefabricated panel houses can be knocked down depends on specific circumstances and cannot be generalized.

1. Brick-Concrete Structure Prefabricated Panel Buildings: Prohibition of Removing Prefabricated Panel Walls If the house is of brick-concrete structure, its prefabricated panel walls usually bear part of the house's weight and are considered load-bearing structures. According to building safety regulations, such walls are strictly prohibited from being removed, nor can doors or windows be opened in them. Unauthorized modifications can disrupt the overall force balance of the house, potentially leading to serious consequences such as structural cracking, settlement, or even collapse. For example, in some old prefabricated panel buildings, the transverse or longitudinal walls directly connect the prefabricated panels to the load-bearing columns. Removing these walls would result in the loss of support for the floor slabs, endangering the safety of occupants.
2. Walls with Safety Hazards: Professional Appraisal Required Before Treatment If the walls of a prefabricated panel building show signs of aging, obvious cracks, deformation, or steel bar corrosion, a professional appraisal by a qualified institution must be conducted first to assess structural safety. According to relevant regulations such as the "Standard for Reliability Appraisal of Civil Buildings," unauthorized removal of walls that may endanger the overall structural safety without appraisal is illegal. If the appraisal results indicate that the hazards can be eliminated through reinforcement and repair (such as carbon fiber cloth reinforcement or adding structural columns), a repair plan should be prioritized. If the repair cost is too high or the wall has completely lost its load-bearing function, the local government may organize demolition in accordance with the "Regulations on the Administration of Urban Dangerous Houses," but it must fulfill legal procedures such as safety assessment and plan publicity to ensure construction safety.
3. Knocking Down Wall Materials and Construction Restrictions: Compliance with Regulatory Requirements Even if a wall has been appraised as removable, strict adherence to material and height restrictions is required during construction. The use of new materials such as lightweight bricks is recommended, as they weigh only one-third of red bricks, reducing the load pressure on the floor slabs and improving construction efficiency by 30%. Additionally, when building walls on secondary slabs (such as prefabricated panel floors), the wall height must not exceed 2.4 meters. Special caution is needed when approaching the height of door frames to avoid cracking of the floor slabs due to excessive local loads. Before construction, the thickness of the floor slab and the configuration of steel bars should be inspected, and temporary supports should be added if necessary.
Summary: Knocking down walls in prefabricated panel houses must be based on structural safety. Priority should be given to clarifying the nature of the walls through professional appraisal, strictly adhering to regulations in selecting materials and construction methods, and avoiding blind modifications.